75W Triple Output Medical Type Features : Universal AC input / Full range Low leakage current<200uA R P T- 7 5 series Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 medical safety approved Fixed switching frequency at 65KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD (23.5CFM) OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) RPT-75A CH1 5V 6A 0.6 ~ 8A 68.5W 93W 120mVp-p 120mVp-p 5.0% 1.0% 1.0% CH2 12V 3A 0.2 ~ 4A CH3 -5V 0.5A 0.1 ~ 1A RPT-75B CH1 5V 6A 0.6 ~ 8A 72W 100W 80mVp-p 2.0% 0.5% 1.5% 120mVp-p 6.0% 1.0% 3.0% 120mVp-p 5.0% 1.0% 1.0% CH2 12V 3A 0.2 ~ 4A CH3 -12V 0.5A 0.1 ~ 1A RPT-75C CH1 5V 6A 0.6 ~ 8A 72W 100W 80mVp-p 2.0% 0.5% 1.5% 150mVp-p 8.0% 1.0% 3.0% 150mVp-p 5.0% 1.0% 1.0% CH2 15V 2.3A 0.1 ~ 3A CH3 -15V 0.5A 0.1 ~ 1A RIPPLE & NOISE (max.) Note.2 80mVp-p CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% 0.5% 1.5% 80ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 76% 1.0% 3.0% 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load 20ms/115VAC at full load 127 ~ 370VDC 77% 77% 1.5A/115VAC 1A/230VAC COLD START 25A/115VAC 50A/230VAC Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A EMS IMMUNITY ISOLATION RESISTANCE 521.2K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/17.4Kg/1.35CUFT ) MTBF OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-75-SPEC 2008-03-25 75W Triple Output Medical Type Features : Universal AC input / Full range Low leakage current<200uA R P T- 7 5 series Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 medical safety approved Fixed switching frequency at 65KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD (23.5CFM) OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) RPT-75D CH1 5V 5A 0.6 ~ 7A 73W 95W 200mVp-p 8.0% 1.0% 3.0% 20ms/115VAC at full load 127 ~ 370VDC 120mVp-p 8.0% 1.0% 3.0% CH2 24V 1.5A 0.1 ~ 2A CH3 12V 1A 0.1 ~ 1A RPT-7503 CH1 3.3V 6A 0.7 ~ 7A 61.8W 81W 80mVp-p -----4.0% 1.0% +3,-4% 120mVp-p 6.0% 1.0% +5,-4% 120mVp-p +10,-6% 1.5% 6.0% CH2 5V 6A 0 ~ 8A CH3 12V 1A 0 ~ 1.5A RIPPLE & NOISE (max.) Note.2 80mVp-p CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 0.5% 1.5% 500ms, 30ms/230VAC 80ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 79% 500ms, 30ms/115VAC at full load 74% 1.5A/115VAC 1A/230VAC COLD START 25A/115VAC 50A/230VAC Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V CH1: 3.8 ~ 4.45V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3 heavy industry level, EN61204-3 medical level, criteria A EMS IMMUNITY ISOLATION RESISTANCE 521.2K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/17.4Kg/1.35CUFT ) MTBF OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-75-SPEC 2008-03-25 75W Triple Output Medical Type Mechanical Specification FAN R P T- 7 5 series Unit:mm 23.5CFM min. 5.7 15cm CN2 CN1 1 2 3 4 5 6 7 8 64.75 76.2 3 2 1 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 45.6 115.8 127 3.8 DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2 3,4,5 6,7 8 Assignment V1 COM V2 V3 Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. V3 3max. 31 fosc : 65KHz +V2 +V1 COM FG O.L.P. CONTROL Derating Curve Output Derating VS Input Voltage Ta=25 133 100 23.5CFM Forced air Cooling 100 90 80 70 Convection Cooling 80 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 70 (HORIZONTAL) 50 60 50 40 20 -20 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RPT-75-SPEC 2008-03-25 |
Price & Availability of RPT-75 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |